Our Technology

We have spent over a decade innovating tools that can consistently capture, image, and deliver living rare cells for downstream analysis. The best of microfluidic design, laser sorting, and fluorescence imaging technology is integrated into our system. What truly sets MiCareo apart is our combination of unique technologies to minimize sample preparation and preserve cell integrity in an automated instrument.

A SelectChip microfluidic cartridge

MiSelect R II System: the whole process in one instrument

From a blood sample to an image of every target cell

  • Biological fluids
  • Automation
  • Microfluidic chip
  • Cell image based
  1. 1

    Sample infusion

    Whole blood is labeled with a sorting marker and infused into the chip.

  2. 2

    Target cell enrichment

    eDAR technology finds the aliquots that hold target cells and sorts them out.

    How eDAR works ↓
  3. 3

    Size-based purification

    On-chip filtration removes red blood cells and smaller white blood cells.

    On-chip filtration ↓
  4. 4

    Staining of enriched cells

    Identification reagents stain the enriched cells in the chip.

    Staining and imaging ↓
  5. 5

    Cell imaging acquisition

    Every cell is imaged for the nucleus, bright field and up to 13 biomarkers.

    Staining and imaging ↓

Steps 1 and 2

eDAR: ensemble-decision aliquot ranking

The MiSelect System is able to process large samples rapidly and yet preserve cell integrity thanks to a technique we developed called ensemble-decision aliquot ranking (eDAR). Instead of treating the whole blood sample as equal, eDAR breaks it down into nanoliter aliquots; only those aliquots containing target cells receive closer investigation, and they are sorted out in milliseconds.

eDAR in action

The process begins by labeling whole blood with a surface antibody, or a cocktail of multiple antibodies. Fluorescently labeled blood enters through the inlet (1) and flows continuously through the laser light. When eDAR detects the presence of target cells (2), it triggers the sorting of the aliquot into a separate chamber for further purification and analysis (3). The rest of the sample flows into the waste chamber (4).

Diagram of eDAR: sample inlet, eDAR selection, isolation, purification and analysis, buffer and waste
Sorting schematic: with a target cell the aliquot is sorted out, without a target cell the blood goes to waste
With a target cell (left) and without a target cell (right)

Step 3

On-chip filtration

In the SelectChip Dual, as the aliquots containing the target cells are collected, on-chip filtration removes blood cells, especially RBCs, and the remaining cells are ready for staining and imaging.

If a non-imaging analysis method is preferred, such as sequencing, the cells can be collected in a microcentrifuge tube with high purity.

On-chip filter: purified cells and antibodies enter, red blood cells and smaller white blood cells are filtered out

Steps 4 and 5

Integrated staining and imaging

Integrated reagent staining

As part of the MiSelect System's automated process, isolated cells are incubated with preloaded antibodies directly in the chip and imaged at 7 different wavelengths. In order to accommodate a wider range of research needs, a second round of reagent staining and imaging allows for the analysis of up to 13 biomarkers on each cell.

Complete automation for reagent labeling and image acquisition.

Antibody and the fluorescence wavelengths used for imaging
One cell imaged with DAPI, bright field and six biomarkers
One cell, imaged for the nucleus (DAPI), bright field and several biomarkers

Cell image analysis

The high resolution images captured by the MiSelect System can be analyzed and reviewed using the bundled software. Cells can be grouped using quantitative measurements of their fluorescent biomarkers, as well as morphological features, such as nuclear size.

Analyzed cells can be used to generate reports on the different numbers and subtypes of cells in the sample.

The MiSelect System analysis software showing imaged cells

MiSelect R II System with SelectChip Retrieval

Live cell retrieval: from billions of cells to one

A single tube of blood holds billions of cells. For those who need to take cell analysis even further, we developed the SelectChip Retrieval cartridge. Rare cells are purified to a high level and output directly into a microcentrifuge tube for downstream analysis such as RNA transcription profiles, DNA mutations, and phenotypic studies.

How the high purity is reached

Whole blood is labeled for the target cells first, which keeps sample loss to a minimum. Then eDAR sorts the sample twice: the first sort enriches the target cells, and the second sort purifies them to near single-cell sorting.

  1. 1

    First eDAR sort

    Initial enrichment: aliquots with target cells are sorted out of the whole blood.

  2. 2

    Cells spread apart

    The microfluidic chip design pulls the cells apart, so the target cells are far from each other when they reach the second sort.

  3. 3

    Second eDAR sort

    Near single-cell sorting: with the cells spread apart, a second sort removes what is left of the unwanted cells.

  4. 4

    Collect in a vial

    The purified cells are collected in a vial of about 150 µL, ready for analysis.

up to 90%
cell recovery
61%
purity of the recovered cells
>98%
viability of the recovered cells

Spike-in test: 40 H1975 lung cancer cells in 8 mL of whole blood. The purity is high enough for downstream analysis such as NGS without a further purification step.

On retrieved CTCs, mutation detection reached a detection rate of 95% or more with as few as 2 to 3 cells, so a mutation can be found from a very small number of isolated cells (NGS or Q-PCR).

See SelectChip Retrieval and HiPure Read our Publications

Performance data

MiSelect R II System performance

Measured by spiking a known number of cancer cells into whole blood.

1 in 8 mL
limit of detection: as few as 1 target cell in 8 mL of whole blood
98%
detection in samples spiked with 1 to 3 cancer cells
100%
analytical specificity: no false detection in healthy donor samples (n=28)
1–512
cells per 8 mL detected precisely: 1, 8, 32, 128 and 512 cells spiked, 6 tests each
10-7
analytical sensitivity down to the 10-7 level
<10%
variation in lab tests, with 90% recovery

Spike-in experiments with cancer cells in 8 mL of whole blood.

Let's Talk


We have Collaboration Service Centers in Taiwan and the USA. Contact us to see our products in action or to have us process your samples.

Map of the world with MiCareo's service centers marked
Taiwan
MiCareo Taiwan Co., Ltd.
5F, No. 69, Lane 77, Xing Ai Road,
Neihu District, Taipei City 114, Taiwan (R.O.C.)
Phone+886 2 2792 3976
Fax+886 2 2791 9833
USA
MiCareo USA
San Jose, California, USA
Collaboration Service Center
Seattle, Washington, USA
Phone+1 650 918 6202
Email
info@MiCareo.com