Automated Single-Cell Liquid Biopsy

RUO All MiCareo products on this page are for Research Use Only. They are not for use in diagnostic procedures.

Rare Cell Diagnostics


MiCareo's technology is founded on research started in 2005. More than a decade of R&D has gone into understanding what researchers and drug development professionals need to usher in the next era of precision medicine. The result of this worthy endeavor is the MiSelect R II System. MiCareo goes beyond the competition in using Liquid biopsy to detect and identify important information in blood.

Talk to us

We capture, stain, and acquire fluorescent multiplexed high-dimensional images of rare cells

Starting from whole blood
Down to a single live cell

Fluorescence image of a single rare cell

Work made simple

Label Whole Blood

Choose our validated sorting reagents or your own cocktail

Choose a marker panel

Select and load the imaging biomarker panel

Let it run

From enrichment to imaging in one afternoon

View the results

Watch your screen light up with a panel of target cells

Characterize the target cells with 7 markers or run an expanded Boost panel for up to 13 markers

Images of one cell in seven channels: Nucleus, EpCAM, Cytokeratin, CD45, BF, Her2, EGFR, PD-L1

The MiSelect System offers more than great results, they are reproducible and fast.

When it comes to patient selection or biomarker discovery, consistent and rapid results are of the utmost importance.

The MiSelect System and the MiSelect R II System achieve 90% cell recovery with less than 10% variation. Best of all, users can confidently expect these results independent of operator experience.

Furthermore, results this important should not take days, or even weeks, to get back from a central lab. Process two samples of whole blood with only 10 minutes of hands on prep, and complete the automated imaging of rare target cells within a few hours, all in your own lab.

A technician loading a SelectChip into the MiSelect R II System
The MiSelect R II System with lab-on-a-chip microfluidics, laser optics, automated reagent perfusion, sample loading and immunofluorescence microscopy labeled
RUO

MiSelect R II System

This all-in-one device houses a fully automated process from cell selection, to antibody labeling, to fluorescence imaging, which ensures that sample loss is minimized and results are reproducible. Our gentle process and integrated instrument give consistent access to isolated live rare cells such as CTCs, and immune cells.

The MiSelect System is compact enough for the corner of your workstation, making it a great fit for any lab, big or small.

Ask for a demonstration

Consumables for the MiSelect R II System

The SelectChip family

Single-use microfluidic cartridges for isolating and imaging rare cells from whole blood. Pick the chip that fits your target cells and your question.

SelectChip Dual in its package
RUO

SelectChip Dual

Two channels on one chip, so you can process two samples at the same time: up to 8 mL in each channel, 16 mL in all. The Dual chips isolate and image rare target cells from whole blood using 7 wavelengths, without the cell shear stress or capacitance issues normally associated with size based separation techniques. Choose the version that suits your work.

  • Dual channels, up to 8 mL × 2 per chip
  • Rapid Dual runs faster than the other Dual chips
  • 2.5 µm or 8 µm slit size, chosen for different target cells
Dual RUO

SelectChip Rapid Dual

Two channels, up to 8 mL × 2, and a faster run than the other Dual chips. Choose it when turnaround matters.

Target cells: circulating tumor cells (CTCs) and rare immune cells.

Dual RUO

SelectChip Dual 2.5 µm

Two channels, up to 8 mL × 2, with a 2.5 µm slit size.

Target cells: stem cells and progenitor cells.

Dual RUO

SelectChip Dual 8 µm

Two channels, up to 8 mL × 2, with an 8 µm slit size.

Target cells: circulating endothelial cells, and other larger cells.

When you need high purity cells

Single channel RUO

SelectChip Retrieval

A single use microfluidic cartridge designed to enrich rare cells and output them into a small volume in a microcentrifuge tube. It sorts whole blood with high purity, allowing for direct coupling to many downstream analysis methods. One channel, one sample at a time.

  • Excellent recovery and high purity enrichment of live rare cells
  • Completely disposable fluid path prevents contamination
  • Gentle processing and low shear stress maintain the integrity of the cells
  • Sort cells from 8 mL of blood in under two hours
HiPure
High purity, fast RUO

SelectChip HiPure

High purity cells, and fast. SelectChip HiPure is suited to measurable residual disease (MRD) research.

Reagents and quality control

Select Kits and MiFluo

Featured kits

Hematology RUO

MiSelect AML MRD LAIP Reagent Kit

For research on measurable residual disease in acute myeloid leukemia, from peripheral blood, with analytical sensitivity at the 10-7 level. It identifies abnormal myeloid blasts by their leukemia-associated immunophenotype (LAIP), with automated classification, and keeps the single-cell images for review.

See the AML MRD study
Neuro-oncology RUO

SelectKit GBM CTC

For research on circulating tumor cells in glioblastoma (GBM), in both cerebrospinal fluid and peripheral blood. Cells are enriched with EGFR and identified with DAPI, EGFR, GFAP and CD45.

See the published study
Oncology RUO

MiSelect CTC Origin Reagent Kit

Goes beyond counting circulating tumor cells: it uses tissue-specific biomarkers to show which tissue the CTCs come from, so a CTC-positive sample tells researchers more about the cancer.

See the biomarkers

All reagents and quality control

MiCareo has designed several reagent kits for isolating CTCs and other rare cells for specific use with the MiSelect System. Use our validated SelectKit combination kits to sort and identify target cells, or pick individual SelectSort and SelectProbe reagents to target your cells of interest.

MiFluo R II RUO is our fluorescent bead quality control solution for the MiSelect R II System, for checking the performance of your system.

MiCareo reagent kits
Sorting RUO

SelectSort reagents

  • SelectSort EpCAM
  • SelectSort EGFR
Oncology RUO

CTC isolation & identification kits

  • SelectKit CTC
  • SelectKit CTC Plus HER2
  • SelectKit CTC Plus PD-L1
  • SelectKit GBM CTC
  • MiSelect CTC Origin Reagent Kit
Hematology RUO

Leukemia MRD

  • MiSelect AML MRD LAIP Reagent Kit
Immunology RUO

Immune cell reagents

  • SelectKit Immuno PD1
  • SelectKit Immuno CTLA-4
Quality control RUO

MiFluo R II

  • Fluorescent bead quality control for the MiSelect R II System

MiCount Cell Analyzer

RUO

The MiCount Cell Analyzer

The MiCount Cell Analyzer

The MiCount Cell Analyzer expands our microfluidic technologies to lower cost cell analysis for cells that are hard to discover with traditional methods. Whether you're working on CD34+ stem cells, regulatory T cells, CAR-T, or circulating endothelial cells, the MiCount Cell Analyzer gives you the power to detect rare sub populations with AI driven automation.

With a detection sensitivity of 10-6 (1 in 1,000,000), the MiCount Cell Analyzer combines targeted cell enrichment with AI-assisted fluorescence detection. The MiCount Cell Analyzer can be placed anywhere and used by anyone with minimal training.

Ask for a demonstration

How the MiCount Cell Analyzer works

It joins target cell enrichment and single-cell fluorescence analysis in one instrument. Because it removes most non-target cells first, the analysis can focus on the few cells that matter, which raises sensitivity to 10-6 and cuts the amount of sample you need.

  1. 1

    Enrich

    A 532 nm laser detects target cells for enrichment and sorting. Specific biomarkers select the target cells, with up to 105-fold enrichment.

  2. 2

    Dilute

    A patented microchannel dilutes the enriched sample more than 400 times, so every cell enters the detection zone on its own.

  3. 3

    Analyze

    488 nm and 638 nm lasers read the cells through 3 fluorescence channels, so 3 biomarkers per cell.

  4. 4

    Report

    Automated, AI-assisted data processing gives a report within 50 minutes, including the analysis.

10-6
detection sensitivity: 1 cell in 1,000,000
50 min
per test, including data analysis and report
No beads
absolute cell counts without adding counting beads

One example is counting live CD34+ stem cells: the MiCount Cell Analyzer needs no red blood cell lysis and no counting beads, and gives the absolute number of live CD34+ cells (cells/µL) and their percentage.

Consumables for the MiCount Cell Analyzer

Chip RUO

SelectCount Chip

The single-use microfluidic chip for the MiCount Cell Analyzer.

Quality control RUO

MiCount QC solution

The quality control solution for the MiCount Cell Analyzer.

Let's Talk


We have Collaboration Service Centers in Taiwan and the USA. Contact us to see our products in action or to have us process your samples.

Map of the world with MiCareo's service centers marked
Taiwan
MiCareo Taiwan Co., Ltd.
5F, No. 69, Lane 77, Xing Ai Road,
Neihu District, Taipei City 114, Taiwan (R.O.C.)
Phone+886 2 2792 3976
Fax+886 2 2791 9833
USA
MiCareo USA
San Jose, California, USA
Collaboration Service Center
Seattle, Washington, USA
Phone+1 650 918 6202
Email
info@MiCareo.com