Find the cell you need

Leukemia Cell-Based MRD, CTC, Glioblastoma (GBM) CTC and Rare Immune Cells, or any rare cell you are interested in

An open platform

Which rare cell are you interested in?

The MiSelect R II System is not built for one cell type. Tell us the cell, choose the right antibodies, and it finds your target cells in whole blood. The examples below are where we have worked so far, not the limit.

1

Choose your antibodies

Use our validated SelectKit combination kits, or pick individual SelectSort and SelectProbe reagents, or your own cocktail, to label the cells you care about. Image up to 13 biomarkers.

2

Choose your chip

Different SelectChips suit different cells: for example CTCs and rare immune cells, stem and progenitor cells, or circulating endothelial cells and other larger cells.

3

See every cell

Automated multiplexed imaging shows each captured cell, and you can retrieve live, high purity cells for single-cell downstream analysis.

See reagents and chips Talk to us about your cells

AML clinical study

Leukemia Cell-Based MRD

Tracking measurable residual disease in AML from a blood draw

The MiSelect R II System is being used in a clinical study of measurable residual disease (MRD) in acute myeloid leukemia.

RUO The MiSelect R II System and the AML MRD LAIP Reagent Kit are for Research Use Only and are not for use in diagnostic procedures.

The MiSelect R II enabled ultra-sensitive, genetic marker-independent MRD detection in peripheral blood (PB), with detectability comparable to RT-qPCR and substantially higher than conventional BM-based MFC.
Read the full statement

MRD negativity was associated with superior RFS and OS, supporting its prognostic value in post-remission monitoring. As a non-invasive platform, MiSelect R II holds broad clinical applicability and supports the feasibility of PB MRD surveillance in AML.

Read the AML posters Talk to us about the study

  • Peripheral blood, non-invasiveMRD detection in peripheral blood instead of bone marrow.
  • Genetic marker-independentDoes not rely on a genetic marker.
  • Sensitivity at the 10-7 levelAnalytical sensitivity for abnormal myeloid blasts, from about 8 mL of peripheral blood.
  • Comparable to RT-qPCRAnd substantially higher than conventional BM-based MFC.
  • Prognostic valueMRD negativity was associated with superior RFS and OS.
  • Prospective multi-center study, enrolling nowThe clinical study has ethics approval and is enrolling patients at hospitals in Taiwan.
  • Presented at ASH, ISLH and EHAPosters are on the Resources page.

CTC: Circulating Tumor Cells


The ability to monitor the level and type of CTCs in a patient's blood provides rich information that is complementary and distinct from all other current diagnostic information. The isolation and purification of circulating tumor cells and the subsequent profiling of their biochemical changes, will greatly enhance both our understanding of cancer metastases, and in the assessment of experimental drugs/treatments.

Illustration of a circulating tumor cell among red blood cells

Power of Enumeration

>90%
sensitivity
<10%
variation

CTC enumeration has numerous potential applications, including monitoring drug response/resistance, predicting the clinical outcome of cancer patients, or detecting potential metastasis early. However, CTC counts in cancer patients could be incredibly low. 10 mL of blood may contain billions of RBCs, millions of leukocytes, and only one CTC.

Although detection, isolation, and analysis of CTCs has posed a challenge in the medical field, MiCareo has consistently achieved a 90% recovery efficiency with less than 10% variation in lab tests.

And unlike many CTC enumeration technologies, the MiSelect System preserves the integrity of isolated cells, affording access to the complete range of genomic as well as cellular information.

Cellular Information

  • Proteomic Biomarkers
  • Functional study

Genomic Information

  • Mutation detection
  • Whole genome
  • Gene expression
Sequencing trace showing an EML4-ALK fusion
EML4-ALK Fusion

Beyond Enumeration

Unlike many CTC imaging systems, the MiSelect System gives researchers the flexibility to access the complete range of genomic and cellular information using our SelectChip Retrieval. Our gentle and minimal processing preserves the integrity of the isolated cells and delivers highly pure cells into a small volume microcentrifuge tube.

Published study

CTCs and prognosis in non-metastatic colorectal cancer

In 8 mL of blood analyzed with the MiSelect System, the presence of CTCs before surgery was linked to worse disease-free survival, and CTCs found 3 to 6 months after surgery were linked to worse outcomes in patients with non-metastatic colorectal cancer.

Read the paper (Scientific Reports, 2023)

MiSelect CTC Origin Reagent Kit RUO

Where do the circulating tumor cells come from?

CTC Origin uses specific biomarkers to identify the tissue of origin of circulating tumor cells (CTCs) in blood samples from cancer patients. It is most useful for research on samples where CTCs have already been detected but the primary site is unknown.

The biomarkers are detected by immunostaining, which identifies the tissue each CTC came from.

See the CTC Origin test at our Taiwan service lab

BiomarkerTarget tissue
CDH17Digestive tract cancers: colorectal, gastric and pancreatic
HepPar1Liver cancer (hepatocellular carcinoma)
PSAProstate cancer
TTF1Lung cancer
Mammaglobin (MMG)Breast cancer
ER & PRBreast, ovarian and endometrial cancers

Published study

Glioblastoma (GBM) CTC

Beyond the blood-brain barrier: circulating tumor cells in high-grade glioma


Glioblastoma is aggressive and often returns after treatment. After treatment, patients are mainly followed with MRI, but treatment-related tissue changes can look like recurrence on an image, and MRI may not reflect tumor biology in real time.

In a published study with a Taiwan medical center, the MiSelect R II System detected circulating tumor cells in both cerebrospinal fluid (CSF) and peripheral blood from patients with IDH-wildtype glioblastoma. At baseline, CTCs were found in CSF in 100% of the 6 patients and in peripheral blood in 83.3%. In some patients whose disease progressed, the number of CSF CTCs rose clearly. Follow-up results on 8 patients were presented at the Asian Society for Neuro-Oncology (ASNO) 2026 meeting.

Read the paper See the ASNO poster

Early results from a small number of patients. Larger studies are needed to confirm them.

100%
CTCs detected in CSF at baseline (6 patients)
83.3%
CTCs detected in peripheral blood at baseline (6 patients)

Rare Immune Cells


Monitoring treatment efficacy is increasingly difficult. Many checkpoint blockades are not found in tumor cells, but inhibitors are instead found acting upon immune cells such as cytotoxic CD8(+) T cells. Profiling immune cells may give more complete information as to cell response or resistance to experimental treatments.

Illustration of rare immune cells

Isolation and Visualization

2-fold more sensitive than FACS at detecting immune cells

Flow cytometry represents the gold standard for accurate determination of specific immune cells. However, as the rarity of the target cells falls to less than 1 in 100,000 background cells, it becomes more difficult to get accurate and absolute sorting and analysis using flow cytometry.

The MiSelect System and the MiSelect R II System were developed specifically for rare cell isolation and identification including rare immune cell profiling. By using the eDAR process the MiSelect System is able to sort and enrich rare immune cells from a background of whole blood.

The MiSelect System shows greater sensitivity in isolating and quantifying rare immune cell subtypes, such as PD1 CD8 IFNγ TIM3 LAG3 positive T cells. In addition, the MiSelect System provides not only numerical data but high-dimensional imaging data for biomarker information.

Using this imaging data, it is possible to subtype rare immune cells. Using PD1, TIM3, LAG3 and IFNg, we can differentiate 16 subtypes of rare immune cells and discover their importance in IO treatments.

Charts comparing cell counts detected by the MiSelect System and flow cytometry in healthy donor samples
High-dimensional imaging panel of an immune cell: BF, DAPI, CD8, PD-1, IFNg, LAG3, TIM3
MiSelect System high-dimensional imaging data

More cells to explore

The search for rare cells in precision medicine is not tied only to CTCs and tumor related immune cells. The potential application of MiCareo's technology is only limited by a researchers willingness to try to better understand rare cells and their uses. We have developed an excellent tool for lighting the way to precision medicine.

Potential use cases

  • Capture the complete genome of fetal cells to detect hereditary disease.
  • Monitor auto-reactive T cells for a better understanding of autoimmune diseases

Let's Talk


We have Collaboration Service Centers in Taiwan and the USA. Contact us to see our products in action or to have us process your samples.

Map of the world with MiCareo's service centers marked
Taiwan
MiCareo Taiwan Co., Ltd.
5F, No. 69, Lane 77, Xing Ai Road,
Neihu District, Taipei City 114, Taiwan (R.O.C.)
Phone+886 2 2792 3976
Fax+886 2 2791 9833
USA
MiCareo USA
San Jose, California, USA
Collaboration Service Center
Seattle, Washington, USA
Phone+1 650 918 6202
Email
info@MiCareo.com